EdenFantasys Newsletter Subscription Form
Take 20% off your order now - Get early access to deals and sales
Home>mall>Tools, Industrial & Scientific
0Liked

AAI ORIGINAL English Verison N1201SA N1201SA+ 34.375MHz-2.7GHz UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester

4.7531
$109.99 /$134.19
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$93.99 /$134.19
Shipping to: United States | Express delivery: 7-12 business days | Standard delivery: 15-25 business days

Guaranteed Safe Checkout

Free Gift
Free gift with any purchase
Shipping Policy
Free standard shipping on orders over $9.9
Return Policy
Return items will be accepted within 40 days when is the date of receiving the goods. Customized items cannot be returned or exchanged. Items bought with an e-gift card are exchangeable only; refunds are not applicable.

Free Gift

Welcome to Roymall, your professional website for purchasing premium department store gifts. We highly value and appreciate your support, and we want to express our gratitude by adding an extra touch of excitement to your purchases. When you shop with us, you not only get to enjoy high-quality products that enhance your lifestyle, but you'll also receive an exclusive free gift with every order you place. Ready to explore our collection and find your perfect gifts? Browse our selection of premium department store items, place your order, and look forward to the excitement of your free gift arriving alongside your purchase.

Shipping Policy

We will work hard to deliver items to you after receiving your orders and make sure they arrive safely. Delivery details will be provided in your confirmation email.In most cases, orders are processed within 2 days.Under special circumstances, it will be delayed as follows: When you place an order on Saturday, Sunday or public holidays, it will be delayed for 2 days..Normally, it needs 5-7 working days (Monday to Friday) without being affected by flight delay or other environmental factors..Because our shipping service is worldwide so the delivery times will depend on your location so it may need a few times and please wait patiently if you are in remote districts or countries.

1. Return & Exchange Policy

We only accept items purchased from roymall.com. If you purchase from our local distributors or other retailers, you cannot return them on our side. Final sales items or free gifts are not acceptable for a return. To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.After receiving return instructions from us, please package up your returned items and drop your package at the local post office or another courier.
We will process your return or exchange item within 3-5 working days after we receive it. The refund will be processed and credited automatically to your original method of payment.No returns or exchanges can be accepted if the product was custom produced, including custom size, custom color, or custom printed.Need more help, please contact us. service@roymall.com or Whatsapp: +8619359849471

2.Refund Policy

You'll get a full refund or 100% store credit after we receive the returned package and check it. The refund will be processed and credited automatically to your original method of payment. Please note that shipping costs and any duties or fees are not refundable. The extra shipping costs are non-refundable once the package has been shipped. You are responsible for paying these fees and we’re unable to waive or refund them, even if the order is returned back to us.Once we received and confirmed your returned item, we will send you an email to notify you that we have received your returned item. We will also notify you of the approval or rejection of your refund.If you have any problems regarding the refund process, please contact us. service@roymall.com or Whatsapp: +8619359849471
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



Startup and shutdown:
Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



Specification:
working currency: 140MHz~2700MHz

stepped frequency: 1kHz

Display: 2.4inch TFT

resolution: 320*240(QVGA)

battery: 2000mAH(7.4Wh)

power consumption: <1.5W

charge current: 400mA

charge port: USB

Auto power off can be set 5-60minutes



Measured parameters:
resistence reactance standing wave s11

resolution ratio: 4 number

frequency accuracy: about 5ppm

Connector: SMA-K

Measurement range:
impedance: 0.1~1000

standing wave: 1.000~65

s11(dB): 0dB~-60dB

Working temperature: 0~40 degree



Package included:
1 x Original N1201SA Antenna Analyzer Meter

1 x English User Manual

Tools, Industrial & Scientific Ranking
Description:
- This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration

The default boot into single-point measurement interface.

Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.



Startup and shutdown:
Hold down the CTRL key off press the power switch button.

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down

The boot state, long press (2S above) the switch button, after the release, the instrument will shut down



Recommend the use:
1, in order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.

2, try to use good quality RF cable and connectors.

3, calibrated cable marked to the next may not need to calibrate and direct use.

4, test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.

5, measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.

6, if the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis



Specification:
working currency: 140MHz~2700MHz

stepped frequency: 1kHz

Display: 2.4inch TFT

resolution: 320*240(QVGA)

battery: 2000mAH(7.4Wh)

power consumption: <1.5W

charge current: 400mA

charge port: USB

Auto power off can be set 5-60minutes



Measured parameters:
resistence reactance standing wave s11

resolution ratio: 4 number

frequency accuracy: about 5ppm

Connector: SMA-K

Measurement range:
impedance: 0.1~1000

standing wave: 1.000~65

s11(dB): 0dB~-60dB

Working temperature: 0~40 degree



Package included:
1 x Original N1201SA Antenna Analyzer Meter

1 x English User Manual

Customer Reviews

4.90 out of 5
See all 16 reviews
Write a Review
  • All Reviews (16)
  • Image ( 1 )
  • Video (0)
  • All Star
    • All Star(16)
    • 5 Star (2)
    • 4 Star (0)
    • 3 Star (0)
    • 2 Star (0)
    • 1 Star (0)
Sort by:
Top Review
  • Top Review
  • Most Helpful
  • Most Recent
Reviews only from your country (United States)
|
Show Original

A part of the review has been auto-translated.

  • 06/08/2023

    Interesting device for RF experimentation and antenna matchin measurement. It cames calibrated, althogh it provides instructions to calibrate it yourself (ou will need special terminal caps for this). Seems to work fine after some basic testing. Instructions manual is quite complete and illustrated.

    Comments (0)
    Show Original
  • 16/04/2025

    Ok.

    Comments (0)
    Show Original
Show:
    12...30

    Total 0 pages

    Go to page

    Go
    Customer Q&As
    Can't find your answer? Ask a new questionorCustomer Service

    Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.

    showing 1-2 of 2 |
    Show Original

    A part of the QA has been auto-translated.

    My Cart Cart (16762)
    My Favorites My Favorites (0)

    Roymall Service